Please send RFIs and RFQs to stan@securepower.io

Schneider Electric, APC, Uniflair, Cooling Distribution Unit 12 Circuit, Bottom/Top Mains, Top Distribution Piping, ACFD12-T
Schneider Electric, APC, Uniflair, Cooling Distribution Unit 12 Circuit, Bottom/Top Mains, Top Distribution Piping, ACFD12-T
Schneider Electric, APC, Uniflair, Cooling Distribution Unit 12 Circuit, Bottom/Top Mains, Top Distribution Piping, ACFD12-T
Schneider Electric, APC, Uniflair, Cooling Distribution Unit 12 Circuit, Bottom/Top Mains, Top Distribution Piping, ACFD12-T
Schneider Electric, APC, Uniflair, Cooling Distribution Unit 12 Circuit, Bottom/Top Mains, Top Distribution Piping, ACFD12-T
Schneider Electric, APC, Uniflair, Cooling Distribution Unit 12 Circuit, Bottom/Top Mains, Top Distribution Piping, ACFD12-T
  • Load image into Gallery viewer, Schneider Electric, APC, Uniflair, Cooling Distribution Unit 12 Circuit, Bottom/Top Mains, Top Distribution Piping, ACFD12-T
  • Load image into Gallery viewer, Schneider Electric, APC, Uniflair, Cooling Distribution Unit 12 Circuit, Bottom/Top Mains, Top Distribution Piping, ACFD12-T
  • Load image into Gallery viewer, Schneider Electric, APC, Uniflair, Cooling Distribution Unit 12 Circuit, Bottom/Top Mains, Top Distribution Piping, ACFD12-T
  • Load image into Gallery viewer, Schneider Electric, APC, Uniflair, Cooling Distribution Unit 12 Circuit, Bottom/Top Mains, Top Distribution Piping, ACFD12-T
  • Load image into Gallery viewer, Schneider Electric, APC, Uniflair, Cooling Distribution Unit 12 Circuit, Bottom/Top Mains, Top Distribution Piping, ACFD12-T
  • Load image into Gallery viewer, Schneider Electric, APC, Uniflair, Cooling Distribution Unit 12 Circuit, Bottom/Top Mains, Top Distribution Piping, ACFD12-T

Schneider Electric, APC, Uniflair, Cooling Distribution Unit 12 Circuit, Bottom/Top Mains, Top Distribution Piping, ACFD12-T

Regular price
$13,299.98
Sale price
$13,299.98
Regular price
Sold out
Unit price
per 

ACFD12-T Features


Cooling Distribution Unit 12 Circuit, Bottom/Top Mains, Top Distribution Piping
Close-coupled, chilled water cooling for medium to large data centers
Includes: Installation guide
  • Coolant balancing
    Provides a central point for fluid balancing.
  • Front service access
    The system has full service, front access for routine servicing of components. Front access also narrows the footprint of the system making it possible for units to be placed side by side.
  • Isolated cooling circuit
    A separate, isolated section which houses all cooling components minimizes the risk of water contacting installed IT equipment in the unlikely event of a leak.
  • Top and bottom chilled water connections
    Provide flexibilty in installation based on the constraints of a given area.

Uniflair Chilled Water InRow Cooling Features & Benefits

Availability

Top and bottom chilled water connections
Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.
Rack inlet control
Rack inlet control guarantees inlet temperature to IT equipment.
Predictable cooling
Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
Dual A-B power inputs
Draws power from the UPS for power protection with dual feeds for redundancy.
Active response controls
Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.

Manageability

Real-Time capacity monitoring
Real-time display of current and available cooling.
Microprocessor controller
Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.
Building management system integration
Send alarms and data points allowing you to manage critical building infrastructure from a single system.

Serviceability

Easy service access
Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.

Total cost of Ownership

Row-based architecture
Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.
Variable speed fans
Variable speed fans reduce energy consumption during off-peak cooling periods.

Agility

Casters
Provides flexibility to move the unit to wherever cooling is required.
Modular design
Modular design provides scalable solutions to add cooling as demand increases.
Scalable densities
Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.

Technical Specifications

Physical

Maximum Height
78.4inches (1991MM, 199.1CM)
Maximum Width
42.1inches (1070MM, 107.0CM)
Maximum Depth
29.5inches (750MM, 75.0CM)
Net Weight
594.28lbs. (269.56KG)
Shipping weight
693.49lbs. (314.56KG)
Shipping Height
85.0inches (2159MM, 215.9CM)
Shipping Width
48.0inches (1219MM, 121.9CM)
Shipping Depth
35.0inches (889MM, 88.9CM)
Color
Black
Units per Pallet
1.0

Conformance

Approvals
MEA
Standard warranty
1 year (parts only)

Sustainable Offer Status

RoHS
Compliant