APC AP7850B Rack PDU, Metered, Zero U, 10A, 230V, (16) C13
APC AP7850B Rack PDU, Metered, Zero U, 10A, 230V, (16) C13
APC AP7850B Rack PDU, Metered, Zero U, 10A, 230V, (16) C13
APC AP7850B Rack PDU, Metered, Zero U, 10A, 230V, (16) C13
APC AP7850B Rack PDU, Metered, Zero U, 10A, 230V, (16) C13
APC AP7850B Rack PDU, Metered, Zero U, 10A, 230V, (16) C13
  • Load image into Gallery viewer, APC AP7850B Rack PDU, Metered, Zero U, 10A, 230V, (16) C13
  • Load image into Gallery viewer, APC AP7850B Rack PDU, Metered, Zero U, 10A, 230V, (16) C13
  • Load image into Gallery viewer, APC AP7850B Rack PDU, Metered, Zero U, 10A, 230V, (16) C13
  • Load image into Gallery viewer, APC AP7850B Rack PDU, Metered, Zero U, 10A, 230V, (16) C13
  • Load image into Gallery viewer, APC AP7850B Rack PDU, Metered, Zero U, 10A, 230V, (16) C13
  • Load image into Gallery viewer, APC AP7850B Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

APC AP7850B Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

Regular price
$429.98
Sale price
$429.98
Regular price
Sold out
Unit price
per 

AP7850B Features

Key Features


Output Connections
(16) IEC 320 C13 (Battery Backup)
Nominal Output Voltage
230V
Nominal Input Voltage
200V, 208V, 230V
Input Connections
IEC-320 C14
Cord Length
10ft (3.05meters)
Rack PDU, Metered, Zero U, 10A, 230V, (16) C13
Metered rack Power Distribution Units (PDUs) provide real-time remote monitoring of connected loads. User-defined alarms warn of potential circuit overloads before critical IT failures occur.
Includes: Cord Retention Bracket(s), Installation Guide, Rack Mounting Brackets, Toolless Mounting Kit

  • Toolless Rack Mounting Capabilities
    Server cases do not require additional tools to mount into NetShelter Enclosures, which allows the users to quickly and easily mount units in the rear of the enclosure.
  • Vertical Mounting Capabilities
    Easily mounts vertically in racks or enclosures and occupies zero U of valuable rack space, which allows more equipment in the rack. Units that mount vertically are optimized to fit in a NetShelter enclosures.

NetShelter Metered Rack PDUs Features & Benefits

Marketing Features

Local Current Monitoring Display
The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.
Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.

Agility

Rack-Mountable
Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.
Single input power source
Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.
Wide range of input and output connections
Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.

Availability

Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)
Local Current Monitoring Display
The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)
Integrates with StruxureWare Data Center Expert
An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
Flash Upgradeable
Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)
Load indicator LED
Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.
Remote Management Capabilities
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.

Technical Specifications

Output

Overload Protection
No
Maximum Total Current Draw
10

Input

Input frequency
47 - 63 Hz
Acceptable Input Voltage
200-250VAC
Number of Power Cords
1
Load Capacity
2300VA
Maximum Line Current
10A

Physical

Maximum Height
49.0inches (1245MM, 124.5CM)
Maximum Width
2.2inches (56MM, 5.6CM)
Maximum Depth
1.75inches (44MM, 4.4CM)
Net Weight
6.75lbs. (3.07KG)
Shipping weight
8.75lbs. (3.98KG)
Shipping Height
84.0inches (2134MM, 213.4CM)
Shipping Width
15.24inches (387MM, 38.7CM)
Shipping Depth
12.7inches (323MM, 32.3CM)
Color
Black

Environmental

Operating Temperature
23 - 113 °F (-5 - 45 °C)
Operating Relative Humidity
5 - 95 %
Operating Elevation
0-10000ft (0-3000meters)
Storage Temperature
-25 - 65 °C
Storage Relative Humidity
5 - 95 %
Storage Elevation
0-50000ft (0-15000meters)

Conformance

Approvals
CE, GOST, VDE
Standard warranty
2 years repair or replace

Sustainable Offer Status

RoHS
Compliant
REACH
REACH: Contains No SVHCs
Battery Directive
Compliant
Proposition 65 Warning
Available in Documentation tab