APC AP7802B Rack PDU, Metered, 2U, 30A, 120V, (16) 5-20
APC AP7802B Rack PDU, Metered, 2U, 30A, 120V, (16) 5-20
APC AP7802B Rack PDU, Metered, 2U, 30A, 120V, (16) 5-20
APC AP7802B Rack PDU, Metered, 2U, 30A, 120V, (16) 5-20
APC AP7802B Rack PDU, Metered, 2U, 30A, 120V, (16) 5-20
APC AP7802B Rack PDU, Metered, 2U, 30A, 120V, (16) 5-20
APC AP7802B Rack PDU, Metered, 2U, 30A, 120V, (16) 5-20
  • Load image into Gallery viewer, APC AP7802B Rack PDU, Metered, 2U, 30A, 120V, (16) 5-20
  • Load image into Gallery viewer, APC AP7802B Rack PDU, Metered, 2U, 30A, 120V, (16) 5-20
  • Load image into Gallery viewer, APC AP7802B Rack PDU, Metered, 2U, 30A, 120V, (16) 5-20
  • Load image into Gallery viewer, APC AP7802B Rack PDU, Metered, 2U, 30A, 120V, (16) 5-20
  • Load image into Gallery viewer, APC AP7802B Rack PDU, Metered, 2U, 30A, 120V, (16) 5-20
  • Load image into Gallery viewer, APC AP7802B Rack PDU, Metered, 2U, 30A, 120V, (16) 5-20
  • Load image into Gallery viewer, APC AP7802B Rack PDU, Metered, 2U, 30A, 120V, (16) 5-20

APC AP7802B Rack PDU, Metered, 2U, 30A, 120V, (16) 5-20

Regular price
$699.98
Sale price
$699.98
Regular price
Sold out
Unit price
per 

AP7802B Features

Key Features


Rack Height
2U
Output Connections
(16) NEMA 5-20R (Battery Backup)
Nominal Output Voltage
120V
Nominal Input Voltage
100V, 120V
Input Connections
NEMA L5-30P
Cord Length
12ft (3.66meters)
Rack PDU, Metered, 2U, 30A, 120V, (16) 5-20
Metered rack Power Distribution Units (PDUs) provide real-time remote monitoring of connected loads. User-defined alarms warn of potential circuit overloads before critical IT failures occur.
Includes: Cord Retention Bracket(s), Installation Guide, Rack Mounting Brackets, User Manual
  • Resettable circuit breakers
    Enables a quick recovery from overload events.

NetShelter Metered Rack PDUs Features & Benefits

Marketing Features

Local Current Monitoring Display
The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.
Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.

Agility

Rack-Mountable
Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.
Single input power source
Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.
Wide range of input and output connections
Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.

Availability

Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)
Local Current Monitoring Display
The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)
Integrates with StruxureWare Data Center Expert
An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
Flash Upgradeable
Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)
Load indicator LED
Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.
Remote Management Capabilities
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.

Technical Specifications

Output

Overload Protection
Yes
Maximum Total Current Draw
24

Input

Input frequency
50/60 Hz
Number of Power Cords
1
Load Capacity
2880VA
Maximum Input Current
30A
Regulatory Derated Input Current (North America)
24A

Physical

Maximum Height
3.48inches (88MM, 8.8CM)
Maximum Width
17.47inches (444MM, 44.4CM)
Maximum Depth
4.41inches (112MM, 11.2CM)
Net Weight
7.4lbs. (3.36KG)
Shipping weight
11.9lbs. (5.41KG)
Shipping Height
5.5inches (140MM, 14.0CM)
Shipping Width
20.0inches (508MM, 50.8CM)
Shipping Depth
14.5inches (368MM, 36.8CM)

Environmental

Operating Temperature
23 - 113 °F (-5 - 45 °C)
Operating Relative Humidity
5 - 95 %
Operating Elevation
0-10000ft (0-3000meters)
Storage Temperature
-25 - 65 °C
Storage Relative Humidity
5 - 95 %
Storage Elevation
0-50000ft (0-15000meters)

Conformance

Approvals
cUL Listed, CSA, FCC Part 15 Class A, ICES-003, UL 60950, UL Listed
Standard warranty
2 years repair or replace

Sustainable Offer Status

RoHS
Compliant
REACH
REACH: Contains No SVHCs
Battery Directive
Compliant