Please send RFIs and RFQs to stan@securepower.io

Schneider Electric, APC, Uniflair, InRow RC, 600mm, Chilled Water, 460-480V, 60Hz, ACRC601
Schneider Electric, APC, Uniflair, InRow RC, 600mm, Chilled Water, 460-480V, 60Hz, ACRC601
Schneider Electric, APC, Uniflair, InRow RC, 600mm, Chilled Water, 460-480V, 60Hz, ACRC601
Schneider Electric, APC, Uniflair, InRow RC, 600mm, Chilled Water, 460-480V, 60Hz, ACRC601
  • Load image into Gallery viewer, Schneider Electric, APC, Uniflair, InRow RC, 600mm, Chilled Water, 460-480V, 60Hz, ACRC601
  • Load image into Gallery viewer, Schneider Electric, APC, Uniflair, InRow RC, 600mm, Chilled Water, 460-480V, 60Hz, ACRC601
  • Load image into Gallery viewer, Schneider Electric, APC, Uniflair, InRow RC, 600mm, Chilled Water, 460-480V, 60Hz, ACRC601
  • Load image into Gallery viewer, Schneider Electric, APC, Uniflair, InRow RC, 600mm, Chilled Water, 460-480V, 60Hz, ACRC601

Schneider Electric, APC, Uniflair, InRow RC, 600mm, Chilled Water, 460-480V, 60Hz, ACRC601

Regular price
$18,929.98
Sale price
$18,929.98
Regular price
Sold out
Unit price
per 

ACRC601 Features

Key Features


Rack Height
42U
Input Connections
Hard wire 4-wire (3P + E)
Close-coupled, chilled water cooling for medium to large data centers
Includes: Installation guide, Operations and maintenance manual

Uniflair Chilled Water InRow Cooling Features & Benefits

Availability

Top and bottom chilled water connections
Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.
Rack inlet control
Rack inlet control guarantees inlet temperature to IT equipment.
Predictable cooling
Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
Dual A-B power inputs
Draws power from the UPS for power protection with dual feeds for redundancy.
Active response controls
Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.

Manageability

Real-Time capacity monitoring
Real-time display of current and available cooling.
Microprocessor controller
Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.
Building management system integration
Send alarms and data points allowing you to manage critical building infrastructure from a single system.

Serviceability

Easy service access
Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.

Total cost of Ownership

Row-based architecture
Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.
Variable speed fans
Variable speed fans reduce energy consumption during off-peak cooling periods.

Agility

Casters
Provides flexibility to move the unit to wherever cooling is required.
Modular design
Modular design provides scalable solutions to add cooling as demand increases.
Scalable densities
Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.

Technical Specifications

Input frequency
60 Hz
Number of Power Cords
2

Communications & Management

Control panel
Multifunction LCD status and control console
Audible Alarm
Audible and visible alarms prioritized by severity

Physical

Maximum Height
78.4inches (1991MM, 199.1CM)
Maximum Width
23.6inches (600MM, 60.0CM)
Maximum Depth
42.1inches (1070MM, 107.0CM)
Net Weight
761.59lbs. (345.45KG)
Shipping weight
893.86lbs. (405.45KG)
Shipping Height
85.3inches (2166MM, 216.6CM)
Shipping Width
33.5inches (850MM, 85.0CM)
Shipping Depth
44.8inches (1137MM, 113.7CM)
Color
Black
Units per Pallet
1.0

Conformance

Approvals
CE, CUL listed, Industry Canada, UL listed, VDE
Standard warranty
1 year (parts only), 1 year on-site repair or replace with factory authorized Start-Up

General

Air Discharge Patterns
Horizontal
Air Flow
6000.0CFM (2831.68lps)
Condensate Pump Capacity
7.9gal/hour (0.01lps)
Intake Air
Rear return
Minimum Water Inlet Temperature
44.6 °F (7.0 °C)