Please send RFIs and RFQs to stan@securepower.io

APC Rack Mounted Air Conditioner with Outdoor Condenser | 3.5 kW Split System 120V
APC Rack Mounted Air Conditioner with Outdoor Condenser | 3.5 kW Split System 120V
APC Rack Mounted Air Conditioner with Outdoor Condenser | 3.5 kW Split System 120V
APC Rack Mounted Air Conditioner with Outdoor Condenser | 3.5 kW Split System 120V
APC Rack Mounted Air Conditioner with Outdoor Condenser | 3.5 kW Split System 120V
APC Rack Mounted Air Conditioner with Outdoor Condenser | 3.5 kW Split System 120V
APC Rack Mounted Air Conditioner with Outdoor Condenser | 3.5 kW Split System 120V
APC Rack Mounted Air Conditioner with Outdoor Condenser | 3.5 kW Split System 120V
  • Load image into Gallery viewer, APC Rack Mounted Air Conditioner with Outdoor Condenser | 3.5 kW Split System 120V
  • Load image into Gallery viewer, APC Rack Mounted Air Conditioner with Outdoor Condenser | 3.5 kW Split System 120V
  • Load image into Gallery viewer, APC Rack Mounted Air Conditioner with Outdoor Condenser | 3.5 kW Split System 120V
  • Load image into Gallery viewer, APC Rack Mounted Air Conditioner with Outdoor Condenser | 3.5 kW Split System 120V
  • Load image into Gallery viewer, APC Rack Mounted Air Conditioner with Outdoor Condenser | 3.5 kW Split System 120V
  • Load image into Gallery viewer, APC Rack Mounted Air Conditioner with Outdoor Condenser | 3.5 kW Split System 120V
  • Load image into Gallery viewer, APC Rack Mounted Air Conditioner with Outdoor Condenser | 3.5 kW Split System 120V
  • Load image into Gallery viewer, APC Rack Mounted Air Conditioner with Outdoor Condenser | 3.5 kW Split System 120V

APC Rack Mounted Air Conditioner with Outdoor Condenser | 3.5 kW Split System 120V

Regular price
$5,487.98
Sale price
$5,487.98
Regular price
Sold out
Unit price
per 

3.5kW split system Indoor unit, Gravity Drain
Close-coupled, Rack Mounted, Air Cooled, Micro Data Center and Edge Application
Includes: 120/240V power supply, Built-in modbus protocol adapter

  • Active response control
    Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and status of the unit is provided.
  • Active response controls
    Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
  • Air filtration
    Removes dirt and other particulates from the intake air for cleaner supply air.
  • Automatic restart
    Returns the unit to its last operating status in the event of a power failure.
  • Compressors
    Scroll and screw compressors utilize few moving parts for increased reliability and life expectancy
  • Counterflow cooling coil
    Designed for high-sensible heat ratios, the coil is constructed with copper tubes, raised lance type aluminum fins, and 18 gauge galvanized steel end plates. Coil headers are equipped with anti-drip shields in the event of condensation.
  • Dehumidification
    Dehumidification is achieved without any reduction in airflow rate, ensuring continuous and uniform air distribution.
  • Ease of Use
    Simplifies future planning by allowing side to side equipment to be placed anywhere in the data center.
  • Easy service access
    Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.
  • Easy to install
    Innovative design allows for fast, easy installation by almost anybody.
  • Efficiency
    Increases the capacity of the air conditioner by supplying a warmer return air temperature.
  • Eliminates Air Mixing
    Isolates hot exhaust air, ensuring consistent supply air to IT equipment.
  • High performance technological solutions
    Optimize the unit operation at any load or ambient condition, guaranteeing an extremely low power consumption
  • Increased capacity
    Higher rate of heat removal allows more equipment to be installed in each rack.
  • Minimizes Air Mixing
    Delivers cool, conditioned air directly to the inlet of IT equipment.
  • Modulating compressors
    Part loading of compressors during start-up ensures low starting torque on the mechanical system with lower inrush current on the electrical system. (only for IS** and BC** models)
  • No minimum heat load requirement
    Refrigerant cooling system will operate from 0 - 100% of the design capacity
  • Noise dampening
    Containment of both front and rear provides reduction of noise caused by installed equipment.
  • Promotes Proper Airflow
    Helps to maintain proper rack temperatures within the enclosure by promoting top to bottom airflow movement.
  • Quick restart
    Full load operation in less than 3 minutes with specific arrangements permits undersizing of the storage tanks
  • Scalable Design
    Modular design provides scalable solutions to add cooling as demand increases.
  • Top or Bottom Piping Connections
    The unit includes both top and bottom piping connections.
  • Variable frequency drives
    Enables the fans to be soft started, saving energy during power up. Controlling the motor speed simplifies the adjustment for static pressure and gives the option of back-draft prevention.
  • Variable Speed Control
    Controls fan speed based on temperature with selectable set points.
  • Variable speed fans
    Variable speed fans reduce energy consumption during off-peak cooling periods.
  • Washable filters
    Easy to maintain, cleanable, deep loading mesh filter removes particles from the return air stream.

Uniflair Rack Mounted Room Cooling Features & Benefits

Total Cost of Ownership

Variable speed fans
Variable speed fans reduce energy consumption during off-peak cooling periods.

Adaptability

Easy to install
Innovative design allows for fast, easy installation by almost anybody.
Modular design
Modular design provides scalable solutions to add cooling as demand increases.

Availability

Active response controls
Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
Redundant Components
Single points of failure in the system have redundant components to maintain availability and reliability.

Serviceability

Easy service access
Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.
Operational Service
Allows critical components to be maintained/replaced while the system is in operation.

Indoor Unit Technical Specifications:

Input

Input frequency
60 Hz
Power Feeds
1.0

Physical

Maximum Height
8.58inches (218MM, 21.8CM)
Maximum Width
18.66inches (474MM, 47.4CM)
Maximum Depth
29.61inches (752MM, 75.2CM)
Net Weight
57.32lbs. (26.0KG)
Shipping weight
66.14lbs. (30.0KG)
Shipping Height
12.99inches (330MM, 33.0CM)
Shipping Width
22.83inches (580MM, 58.0CM)
Shipping Depth
37.4inches (950MM, 95.0CM)

Environmental

Operating Temperature
-4 - 122 °F (-20 - 50 °C)
Operating Relative Humidity
20 - 80 %
Storage Temperature
-20 - 50 °C
Audible noise at 1 meter from surface of unit
74.0dBA

Conformance

Approvals
UL Listed
Standard warranty
1 year (parts only)

Outdoor Unit Technical Specifications:

Input

Input frequency
60 Hz
Input Power
1.0Watts

Physical

Maximum Height
24.29inches (617MM, 61.7CM)
Maximum Width
33.7inches (856MM, 85.6CM)
Maximum Depth
11.65inches (296MM, 29.6CM)
Net Weight
101.41lbs. (46.0KG)
Shipping weight
114.64lbs. (52.0KG)
Shipping Height
28.46inches (723MM, 72.3CM)
Shipping Width
41.34inches (1050MM, 105.0CM)
Shipping Depth
18.9inches (480MM, 48.0CM)

Environmental

Audible noise at 1 meter from surface of unit
50.0dBA

Conformance

Approvals
UL Listed
Standard warranty
1 year (parts only)